LAB-4BF+4*SL0107B split independent control micropump

Four-channel independent micro-injection pump with split control; one controller can independently control 1-4 actuators for micro-injection, suitable for applications in veterinary medicine.

    LAB-4BF+4*SL0107B split independent control micropump

    • Product Description
    • Commodity name: LAB-4BF+4*SL0107B split independent control micropump

    Four-channel independent micro-injection pump with split control; one controller can independently control 1-4 actuators for micro-injection, suitable for applications in veterinary medicine.

    Product Introduction

    The LAB-4BF+4*SL0107B is a split-structure, 4-channel independently controlled injection pump. One controller can independently control 1-4 actuators to achieve micro-injection, which is ideal for the animal medical field.
    4-Channel Completely Independent Characteristics: 4-channel independent control, independent operation, independent calibration. Each channel can be configured with different syringes and different operation modes.
    Touch Screen Display: 7-inch high-definition touch screen, simple, clear, easy to understand, and easy to operate.
    Syringe Selection: Built-in major domestic and international manufacturers, main model syringes are selectable, and custom syringes are supported.
    Calibration Function: Supports syringe calibration and stores calibration parameters.
    Parameter Setting: Volume, flow rate, infusion time, withdrawal time, interval time, and infusion times are settable and storable.
    Online Speed Adjustment: The current flow rate can be adjusted during operation.
    Power-on Operation: Stores the current dynamic operating parameters when the power is off and continues operation when the power is on.
    Prompt Function: Real-time display of available Max/Min flow rate; dynamic display of relevant operating parameters.
    Reminder Function: When the set target volume is reached during operation, an audible alarm will prompt.
    Thrust Setting: Appropriate thrust can be set according to the syringe specifications.
    External Control Start/Stop: External control level signal (5-24V) or contact signal can be used to achieve simultaneous start/stop control of the four channels.
    Communication Control: RS485/USB optional, touch control address and baud rate settings.
    Status Output: Start/stop and direction status output

    Typical Applications

    High-precision injection of liquid medicine into animals.
    Microfluidic chip liquid injection.
    Injection of liquid medicine into the animal brain.
    Continuous infusion of micro-flow liquid.
    Micro-drop addition of reagents in the reactor

    Technical Parameters

    Product Model

    LAB-4BF+4*SL0107B

    Linear Thrust

    ≥25N (any channel)

    Linear Velocity Range

    0.12μm/min ~121.92mm/min

    Stepping Resolution

    0.190μm/μstep

    Travel Control Accuracy

    Error ≤ ±0.1%

    Travel Distance

    70mm

    Syringe Specifications

    0.5μL~250μL

    Touch Control Display

    1024*600 7-inch high-definition touch screen, easy to operate, clear and concise information

    Language Types

    Chinese and English, 2 languages selectable

    Independent Channel Function

    4-channel independent control, independent operation, independent calibration. 4-channel independent syringe configuration, independent work mode configuration. Each channel can select any one of the following modes: infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous, multiple infusions.

    Pre-Start Function

    4-channel independent pre-start time setting, time setting range is 0-6553.5, sec/min/hour time unit selectable

    Parameter Setting

    4-channel independent setting of syringe, volume, flow rate, infusion time, withdrawal time, and interval time, and independent storage

    Syringe Selection

    4-channel independent built-in major domestic and international manufacturers, main model syringes are selectable, and custom syringes are supported

    Online Speed Adjustment

    4-channel independent speed adjustment during operation

    Calibration Function

    4-channel independent syringe calibration and independent storage of calibration coefficients

    Prompt Function

    4-channel real-time display of their respective available maximum and minimum flow rates; dynamic display of the operating parameters of the 4 channels

    Reminder Function

    4-channel audible alarm when the set target volume is reached

    External Control Function

    Start/stop of the 4 channels is independently controlled by external signals or contacts. Control modes: high level (5-24V), low level, pulse selectable

    Foot Switch

    Φ6.35 foot switch jack, total start/stop control of 4 channels via foot switch

    Communication Control

    RS485/USB optional, touch control address and baud rate settings

    Status Output

    4-channel independent output of start/stop and direction status

    Applicable Power Supply

    AC 90V~264V 50/60Hz

    Operating Environment

    Temperature: 0~40℃ Humidity: 20%-80% RH, no condensation

    Storage Environment

    Temperature: -10~60℃ Humidity: 20%-80% RH, no condensation

    Protection Level

    IP31

    Product Dimensions (mm)

    Controller: 262*149*90 (mm) Actuator: 163*34*34 (mm)

    Selection Guide

    Injection Pump Model

    Syringe Capacity

    Syringe Inner Diameter (mm)

    Reference Flow Rate Range (pL/min-uL/min)

    LAB-4BF/4*SL0107B

    0.5μL

    0.10

    0.96~0.96

    1μL

    0.15

    2.15~2.15

    2μL

    0.20

    3.83~3.83

    5 μL

    0.35

    11.73~11.73

    10 μL

    0.50

    23.94~23.94

    25 μL

    0.80

    61.28~61.28

    50 μL

    1.10

    115.86~115.86

    100μL

    1.60

    245.13~245.13

    250 μL

    2.30

    506.55~506.55

Get a free product quote

Fill in your phone and E-mail information, and we will contact you within one working day to solve your problems as soon as possible.