TSP-1BF+L0107 Single-Channel Split Syringe Pump
Category:
Tags:
- Product Description
TSP-1BF+L0107 Single-Channel Split Syringe Pump
-
- Commodity name: TSP-1BF+L0107 Single-Channel Split Syringe Pump
Single-channel injection/withdrawal microinfusion pump, suitable for微量 high-precision liquid delivery. The injection is primarily used in the field of animal experiments, in conjunction with stereotaxic brain apparatus and micromanipulators.
Product Introduction
◆ The TSP-1BF+L0107 is a single-channel, injection/extraction-type micro-dispensing pump suitable for highly precise injection of small volumes of liquid.
◆ Primarily used in the field of animal experimentation, in conjunction with a stereotaxic brain apparatus and a micromanipulator.
◆ Flow range: 0.00265 nL/min – 2.79 mL/min
◆ Compact in size, with a separate structure for the controller and the actuator unit.
◆ Touchscreen display: 4.3-inch HD touchscreen, simple, clear, and easy to operate.
◆ Working modes: Four optional working modes—Injection, Withdrawal, Withdrawal first then injection, and Injection first then withdrawal.
◆ Power-loss memory function: Saves the setting parameters, so you don’t need to reconfigure them after power is restored.
◆ Online speed adjustment: The current flow rate can be adjusted during operation.
◆ Multiple scenarios can be pre-stored for easy recall.
◆ Liquid volume calibration function: The calibration procedure enables more accurate flow measurement.
◆ Communication Control: RS485/USB Optional
Typical applications
◆ Biological laboratory
◆ Animal drug injection using a stereotaxic brain apparatus
◆ Microvolume liquid injection
Operation interface

Technical Parameters
Work mode Injection, withdrawal, withdraw first then inject, inject first then withdraw Flow range 0.00265nL/min-2.79mL/min Number of installable injectors 1 Range of installable injectors 0.5ul-1000ul Trip distance 70mm Trip resolution 0.124 μm Linear velocity range 0.3715 µm/min – 158.75 mm/min (Flow rate = Linear velocity × Cross-sectional area of the syringe) Travel control accuracy Error ≤ ±0.1% Touch display 4.3-inch HD touch screen, easy to operate Language types Chinese and English, two languages available Calibration function Supports liquid volume calibration and stores calibration coefficients. Syringe Selection Built-in syringes from major domestic and international manufacturers are available for selection, and customization is supported. Parameter Settings Liquid volume, flow rate, injection time, withdrawal time, interval time, and number of injections can be set and stored. Scheme storage Pre-store multiple solutions for easy retrieval. Online speed adjustment During operation, change the running speed or running time, and after confirmation, execute according to the new parameters. Reminder function Run to the set target liquid volume, with an audible alarm prompt. Appointment feature Automatically start and run at the set date and time. External control function Start-stop control is managed by external signals or contacts; control modes include: high level, low level, and pulse—selectable. Communication control RS485/USB optional; touch-screen settings for address and baud rate. Applicable power supply AC 90–264 V 50/60 Hz Work environment Temperature: 0–40℃, Humidity: 20%–80% RH, No condensation. Selection Guide
Syringe pump model
Applicable Injector Specifications
Injector inner diameter (mm)
Reference Flow Range (nl/min – ul/min)
TSP-1BF+L0107
0.5 μL
0.10
0.00265–1.32
1 μL
0.15
0.0053–2.66
2.5 μL
0.21
0.0106–5.29
5 μL
0.34
0.0293-14.67
10 μL
0.49
0.0599–29.94
25 μL
0.73
0.1325–66.26
50 μL
1.03
0.2646 - 132.28
100 μL
1.46
0.5294 - 264.68
250 μL
2.30
1.33–661.86
500 μL
3.26
2.65-1320
1000 μL
4.73
5.58-2790
External dimensions


Operation video