LAB-2D Independent Control Injection Pump

Dual-channel independent control intelligent injection pump, not only can achieve dual-channel completely independent, but also can achieve dual-channel linkage, suitable for complex applications of micro-liquid processing

    LAB-2D Independent Control Injection Pump

    • Product Description
    • Commodity name: LAB-2D Independent Control Injection Pump

    Dual-channel independent control intelligent injection pump, not only can achieve dual-channel completely independent, but also can achieve dual-channel linkage, suitable for complex applications of micro-liquid processing

    Product Introduction

    The LAB-D series laboratory syringe pumps not only achieve dual-channel complete independence but also dual-channel linkage, suitable for complex applications of micro-liquid handling.

    Touchscreen Display: 5-inch high-definition touch screen, simple, clear, easy to understand, and easy to operate

    Syringe Selection: Built-in syringes from major domestic and international manufacturers, and supports customization.

    Calibration Function: Supports syringe calibration and stores calibration parameters.

    Parameter Settings: Liquid volume, flow rate, infusion time, extraction time, interval time, and infusion times are settable and storable.

    Online Speed Adjustment: The current flow rate can be adjusted during operation.

    Power-on Operation: Stores current dynamic operating parameters when power is off and continues operation after power-on.

    Prompt Function: Real-time display of available Max/Min flow rates; dynamic display of operating parameters.

    Reminder Function: When the set target liquid volume is reached, a sound alarm will prompt.

    Thrust Setting: Appropriate thrust can be set according to the syringe specifications.

    External Control Start/Stop: External control level signal (5-24V) or contact signal to achieve start/stop control.

    Communication Control: RS485/USB optional, touch control settings for address and baud rate.

    Status Output: Start/stop, direction status output.

    Typical Applications

    Biological Laboratory

    Electrophysiology, chemistry, pharmaceuticals, etc.

    Micro-liquid infusion.

    Electrospinning

    Technical Parameters

    Specifications and Models LAB-2D
    Working Mode 2-channel independent control, independent operation, independent calibration. 2-channel independent syringe configuration, independent working mode configuration. Each channel can select any mode from infusion, extraction, infusion/extraction, extraction/infusion, continuous, and multiple infusions.
    Dual-Channel Linkage Function 2-channel linkage operation, realizing complex working processes such as 2-channel reciprocation, 2-channel synchronization, and 2-channel synchronous confluence.
    Number of Channels 2
    Maximum Stroke 150mm
    Syringe Specifications 0.5uL-100mL
    Linear Thrust 160N
    Stepping Resolution 0.0625um/ustep
    Linear Velocity Range 0.08um/min-160mm/min
    Stroke Control Accuracy Error ≤ ±0.1%
    Touchscreen Display 800*480 5-inch high-definition touch screen, easy to operate, clear information.
    Language Types Chinese and English, 2 languages selectable
    Online Speed Adjustment The current flow rate can be adjusted during operation.
    Calibration Function 2-channel syringes can be calibrated independently and calibration coefficients stored independently.
    Syringe Selection Built-in syringes from major domestic and international manufacturers, and supports customization.
    Parameter Settings 2-channel independent settings for liquid volume, flow rate, infusion time, extraction time, interval time, and infusion times are settable and storable.
    Power-on Operation Stores current dynamic operating parameters when power is off and continues operation after power-on.
    Prompt Function Real-time display of available maximum/minimum flow rates; dynamic display of operating parameters.
    Reminder Function When the set target liquid volume is reached, a sound alarm will prompt.
    Thrust Setting Appropriate thrust can be set according to the syringe specifications.
    External Control Function Start/stop control by external signal or contact, control methods: high level (5-24V), low level, pulse optional.
    Foot Switch 6.35 foot switch jack, start/stop control via foot switch.
    Communication Control RS485/USB optional, touch control settings for address and baud rate.
    Status Output Start/stop, direction.
    Applicable Power Supply AC 90-264V 50/60Hz
    Working Environment Temperature: 0-40℃ Humidity 20%-80% RH no condensation
    Protection Level IP31
    Dimensions 256*190*146 (mm)

    Selection Guide

    Syringe Pump Model

    Syringe Capacity

    Syringe Inner Diameter (mm)

    Reference Flow Rate Range (nL/min-mL/min)

    LAB-2D

    0.5μL

    0.103

    0.0007-0.0013

    1 μL

    0.146

    0.0013-0.0027

    2 μL

    0.206

    0.0027-0.0053

    5 μL

    0.343

    0.0074-0.0148

    10 μL

    0.485

    0.0148-0.0295

    25 μL

    0.729

    0.0334-0.0668

    50 μL

    1.03

    0.0667-0.1333

    100 μL

    1.457

    0.1334-0.2668

    250 μL

    2.304

    0.3335-0.6671

    500 μL

    3.256

    0.6658-1.3320

    1ml

    4.73

    1.4060-2.8110

    2ml

    8.92

    4.9990-9.9980

    2.5ml

    8.92

    4.9990-9.9980

    5ml

    12.4

    9.6620-19.3220

    10ml

    14.87

    13.8940-27.7860

    20ml

    19.07

    22.8500-45.6990

    30ml

    23.36

    34.2870-68.5730

    50ml

    28.95

    52.6600-105.3190

    60ml

    29.47

    54.5680-109.1360

Get a free product quote

Fill in your phone and E-mail information, and we will contact you within one working day to solve your problems as soon as possible.