LSP10-1B

10-channel syringe pump for perfusion, mainly used in biological laboratories, with an integrated structure.

    LSP10-1B

    • Product Description
    • Commodity name: LSP10-1B

    10-channel syringe pump for perfusion, mainly used in biological laboratories, with an integrated structure.

    Product Introduction

    The LSP10-1B micro-injection pump is a 10-channel aspiration and perfusion injection pump, mainly used in biological laboratories, with an integrated structure.

    Able to accommodate syringes (injectors) of different specifications, the LSP10-1B micro-injection pump is suitable for high-precision, low-flow liquid transfer.

    Mainly used in the laboratory field, for micro-liquid perfusion applications

    Flow rate range: 0.831nl-21.675ml/min

    Able to accommodate injectors or syringes of different specifications

    The micro-injection pump has a user-friendly human-machine interface: large-screen LCD display, digital knob and membrane key combination, easy and quick operation.

    Working mode: Single push working mode.

    Power-off memory function: Saves setting parameters, no need to reset after power-on.

    Using a 485 communication bus, it can be connected to a host computer for control via backend software.

    External control interface: Has input/output control functions.

    Liquid volume calibration function: A more accurate flow rate can be obtained through the calibration program.

    Typical Applications

    Biological Laboratories

    Micro-liquid perfusion

    Operation Panel

    Technical Parameters

    Product Model LSP10-1B
    Working Mode Perfusion, aspiration, aspiration then perfusion, perfusion then aspiration, continuous
    Flow Rate Range 0.001ul-28.135ml/min
    Number of Syringes that can be installed 10
    Applicable Syringe Specifications 10uL-10mL
    Stroke Distance 140mm
    Stroke Resolution 0.156μm
    Linear Velocity Range 5μm/min-130mm/min (Flow rate = Linear velocity × Syringe inner cross-sectional area)
    Linear Velocity Adjustment Resolution 5μm/min
    Stroke Control Accuracy Error ≤ ±0.5% (When stroke ≥ 30% of stroke distance)
    Rated Linear Thrust >280N
    Syringe Selection Built-in syringes from major manufacturers and models are available for selection
    Syringe Customization The inner diameter of the syringe can be directly input
    Flow Rate Calibration Obtain a more accurate liquid volume through the calibration program
    Running Parameter Settings Dispensing volume, injection time, etc.
    Display Parameter Selection Volume, flow rate or linear velocity
    Power-off Memory After power-on, you can choose whether to continue working according to the status before power-off
    Status Signal Output 2-way OC gate signal output, used to indicate start/stop and direction status
    Control Signal Input 2-way start/stop control input terminals, 1-way falling edge trigger signal controls start/stop; 1-way TTL level signal controls start/stop
    Communication Interface RS485
    External Dimensions 280×210×140(mm)
    Weight 6.5kg
    Power Supply AC 90V-260V/30W
    Working Environment Relative Humidity <80%
    Working Environment Temperature 0℃-40℃

    Selection Guide

    Injection Pump Model

    Applicable Syringe (or Injector) Specifications

    Applicable Syringe Inner Diameter (mm)

    Reference Flow Rate Range (μl/min-ml/min)

    LSP10-1B

    10μl

    0.50

    0.001-0.0255

    25μl

    0.80

    0.0025-0.0653

    50μl

    1.10

    0.0048-0.1235

    100μl

    1.60

    0.0101-0.2614

    250μl

    2.30

    0.0208-0.5401

    500μl

    3.25

    0.0415-1.0784

    1ml

    4.72

    0.0875-2.2747

    2ml

    9.00

    0.3181-8.2702

    5ml

    13.10

    0.6739-17.522

    10ml

    16.60

    1.0821-28.135

Get a free product quote